1Vehicle / Job Information
Start clean2Relay / Terminal Identification
Map it firstDo not assume every relay uses the same cavity numbering or control strategy. Record the actual diagram and terminal function before interpreting voltage.
Common / Feed
Coil Side A
Coil Side B
Normally Open Output
Normally Closed
3Command & Hold Condition
Lock the event4Electrical Capture — OFF, Pull-In, Hold / Fault
Same referenceUse the same meter reference and same terminal map for all three captures. Record the voltage across the coil directly when possible; terminal-to-ground readings alone can mislead on high-side, low-side, PWM, or floating control circuits.
A — Commanded OFF Baseline
Before pull-in. Establish feed and resting control state.
B — Initial Pull-In
Capture immediately as the relay is commanded ON.
C — Held State / Fault Point
Capture while the relay should still be ON, especially at dropout or chatter.
5Controlled Change / Repeat Test
One move6Drift / Safety / Evidence Quality Check
Trust the setup7Final Result / Conclusion
Evidence-ownedChoose the result that the measurements support. These are routing categories, not automatic component condemnations.