Inputs:
- Pressure units: psi or kPa. Tool math uses your selected units (no unit conversion inside the math).
- Time (min): minutes after shutdown. Enter points in increasing time order (0, 2, 5, 10, ...).
- Minimum time window: optional guardrail. If your last point is under this window, the tool will warn you to capture longer data.
- Stabilized tail band: optional comparison band for the tail segment rate (units/min). Smaller tail rate suggests the system is holding residual pressure.
Math used (frozen):
- Total time: T = t_last - t_first
- Total drop: D = p_first - p_last
- Average decay rate: R_avg = D / T (units per minute)
- Early segment rate: R_early = (p1 - p2) / (t2 - t1) using the first two valid points
- Tail segment rate: R_tail = (p_(n-1) - p_n) / (t_n - t_(n-1)) using the last two valid points
- Early vs tail ratio: Ratio = R_early / max(R_tail, tiny) where tiny = 0.000001 to avoid divide-by-zero
Interpretation (pattern bands, not a verdict):
- Normal sealed behavior: small average rate + tail rate within your stabilized band.
- Steady decay: early and tail rates are similar (ratio near 1). This can be seen with leakage paths that stay open over time.
- Fast early drop, then slows: ratio is high (early much larger than tail). This is often associated with bleed-back style behavior.
Related SpeedNeeds explainer: Residual fuel pressure leakdown
Related QTS (conditional): If your decay pattern looks like steady loss, it may be useful to compare it against QTS-FUEL-C1 language. If the loss is mostly early and then stabilizes, it may be useful to compare it against QTS-FUEL-C2.