Inputs: Source voltage is your reference point in volts. Cylinder / injector count builds the active row count for the current engine. Measured injector feed voltage is the actual voltage seen at each injector feed during the same test state. Max allowed drop is your chosen cutoff. Test state and notes are log-only fields.
Formula frozen in code: drop = sourceVoltage - measuredInjectorVoltage
Percent drop: dropPercent = (drop / sourceVoltage) × 100
Status logic: PASS when drop is less than or equal to the threshold, WATCH when drop is above the threshold but not more than 125% of it, FAIL when drop is greater than 125% of the threshold. Negative drop values are kept visible so bad reference picks or meter issues stand out.
Edge cases: Blank or invalid rows stay as an em dash and are excluded from summaries. A source voltage less than or equal to zero is rejected. Cylinder / injector count is required so row count cannot silently skew the outcome. The tool stops if count, source voltage, or threshold are missing or invalid. No auto-calc.