SpeedNeeds
SpeedNeeds Tool

Fuel Pump Command Logic Mapper

Tight scope: map who is allowed to command the pump right now. This clarifies ECU enable, relay coil control, security inhibit, and RPM dependency so you do not run the wrong A-test first.

This matters because many systems allow prime at KOEO, then require RPM once cranking/running.
Pick what the ECU actually does: ground coil, power coil, or command a driver/module.
Prime behavior tells you what should happen at KOEO before cranking.
If YES, chasing feed power at KOEO can waste time. You must test under crank/run.
If security can inhibit, the ECU may "want" fuel but never enable the pump.
These can kill pump power even when the relay and ECU are doing their job.
This does not change logic, it just prints into the map so you keep your head straight.
Primary commander
--
ECU enable expected?
--
Relay / driver action
--
Most important dependency
--
Copy this into your notes. It is the "who is allowed to command the pump" snapshot.
Notes and logic
  • Prime window: If the system primes at KOEO, it may only run the pump for a short time, then shut it off until it sees RPM/crank.
  • RPM dependency: If pump enable depends on RPM, do not judge "pump power" based only on KOEO checks. Test under crank/run.
  • Security inhibit: Security can block the enable even when the ECU has power and ground. Treat it as a gate until proven otherwise.
  • Secondary cut devices: Inertia and oil pressure switches can open pump power after the relay, making you chase the wrong end.
  • What this tool is NOT: It is not a diagnostic. It is an orientation map so you start on the right A-test.
Purpose of this tool

This tool exists to keep you oriented before you ever touch a meter or run a test.

It helps prevent three common mistakes:

  • Proving the wrong thing - testing power, ground, or the pump itself when the system is not allowed to command it.
  • Testing in the wrong state - checking pump behavior at KOEO when the logic only applies during crank or run.
  • Testing with the wrong expectation - assuming the pump should be on continuously when prime windows, RPM dependency, security inhibits, or cut devices say otherwise.

This tool is here to prevent you from proving the wrong thing, in the wrong state, with the wrong expectation.

The output is an orientation snapshot. It tells you who can command the pump and under what conditions - not what failed and not what to replace.

Get new drops in your inbox

Read the Privacy Policy.