Inputs
- Prime, Crank, Run, Hold are pressure snapshots in psi.
- Hold time is the elapsed time between Run and Hold snapshots (seconds).
Outputs
- Prime - Crank delta = Prime psi minus Crank psi
- Crank - Run delta = Crank psi minus Run psi
- Run - Hold drop = Run psi minus Hold psi
- Drop rate = (Run psi minus Hold psi) / Hold seconds
Hold timer behavior
- Click Calculate once to start the hold timer (requires Run pressure).
- Click Calculate again to stop and auto-fill Hold seconds.
- After you enter Hold pressure, click Calculate to compute outputs.
delta = A - B
drop_rate (psi/sec) = (run - hold) / seconds
drop_rate (psi/sec) = (run - hold) / seconds