Intermittent fault time-domain correlation

Catching an intermittent means recording when it happens, not just that it happened. And proving it twice.

Conceptual definition

Intermittent fault time-domain correlation is a scope method for catching faults that come and go. You record two channels on the same clock at the same time: one on the branch under suspicion, one on a reference point you trust. Then you line the two traces up by time and ask what the reference was doing at the exact instant the branch misbehaved.

The method is when-vs-what capture. The WHEN is the fault event on the branch trace. The WHAT is the state of the reference at that instant. Together they bound the fault to a segment of the circuit, or they point the search upstream or downstream.

Without the reference, a glitch on the branch trace is just a glitch. Without time alignment, two traces are two stories. The correlation is the evidence.

Why it varies

Every part of the setup changes what the capture can prove, so the method varies with the fault it is hunting.

What it is not

It is not a multimeter snapshot, and it is not "we saw a glitch once."

It is not proof the circuit is good because the reference looked clean. A clean trace during a calm moment says nothing about a fault that never fired.

It does not name the bad component. The method bounds the fault to a segment of wire, connectors, and contacts between probe points. Segment-level, never part-level.

Failure modes

The method fails in known ways, and every one of them looks like a success if you are not watching for it.

How SpeedNeeds uses it

SpeedNeeds uses time-domain correlation as the backbone of its intermittent-fault diagnosis. When a fuel or ignition test hits an intermittent that will not hold still, the routing points here.

The procedure runs two separate recording sessions with physically distinct contacts, checks channel contact against a known-potential jumper, and carries honest terminals for every dead end: no event captured means unproved, not clean; a single event means suspect, not convicted; indeterminate current means indeterminate, never a verdict.

Stop guessing. Prove the next move. Two channels, one clock, two confirmed events, and the trace pair is the proof.

Caution and edge cases

Signal and high-impedance circuits are out of domain. The current-signature exclusion logic only holds on passive, damped power feeds. On a signal circuit, the same traces mean different things.

A heavy downstream shunt can pull both probes down together, which looks like an upstream fault until the current check at the branch end is run. Never skip the current check.

On regulated-load circuits where the tech cannot bound the current response from service information, the procedure honestly ends indeterminate. That is the method working, not the method failing.

Closing clarity

Time-domain correlation is discipline, not equipment. Catch the instant it fails, compare it against a reference that did not fail at that instant, and prove it twice.

One channel is a suspicion. Two channels on one clock is an argument. Two channels, one clock, two confirmed events: that is a verdict.